Oracle Solution for Error ora-16216

Solution for Oracle Error ORA-16216

ORA-16216: Log stream sequence error

What triggered the Error:

The log stream being processed did not follow the last processed stream.

What should we do to fix it:

If the database is in an active configuration, issue an ALTER DATABASE START LOGICAL STANDBY APPLY NEW PRIMARY command to synchronize log stream data with the current primary database. If the database is not in an active configuration, manually add the next dictionary-begin logfile that followed the previous log stream.